A prospective client is very interested in the IBM Flex System, and they want to standardize on the x240. The client is very concerned with tape back-up and needs to keep Internet traffic, tape traffic, and disk traffic on separate physical adapters. How can this be achieved?
A. Add a redundant CN4093 switch
B. Add a PCIe expansion node
C. Add a storage expansion node
D. Add a redundant Fibre Channel switch
正解:B
質問 2:
Exhibit:
The client has a strong skill base/interest in a Linux RHEL-based virtualized solution. One of their key requirements is to be able to quickly provision new compute nodes. Which PureFlex systems management capability should be highlighted to them?
A. Capture and redeployment of virtual machines
B. Relocation of virtual machines based upon PFA events
C. Bare-metal OS deployment
D. Multiple hypervisor management
正解:C
質問 3:
Which I/O modules can support end-to-end FCoE between a compute node with a CN4054 10Gb Adapter (with the FCoE upgrade) and an IBM Flex System V7000 Storage Node?
A. Any IBM 10Gb Ethernet I/O module
B. Only the CN4093
C. Only the EN4093R
D. Any IBM Fibre Channel I/O module
正解:B
質問 4:
Exhibit: Given the client's need for a low-cost solution, the IBM sales team decided to propose an Express foundation configuration, adding a second IBM Flex System Fabric EN4093R 10Gb Scalable Switch to eliminate the network single point of failure.
IBM 000-784 Exam
Which of the following is a true statement about the added 10Gb Scalable Switch module?
A. The second switch module will come fully cabled and configured just like the first switch module, and the Lab Services team will connect itinto the client network as part of their normal Statement of Work
B. The second switch module will come with a factory-default configuration that is unlike the first switch module, it will not be cabled to anything,and it will be out of scope of the Lab Services normal Statement of Work
C. The second switch module will come fully configured just like the first switch module, but not cabled, and that switch will be out of scope ofthe Lab Services normal Statement of Work
D. The second switch module will come fully cabled and configured just like the first switch module; however, that switch will be out of scope ofthe Lab Services normal Statement of Work
正解:B
質問 5:
The IBM Flex System Interoperability Guide is a handy reference document but its information is only as accurate as of its most recent publication date. Where would the technical expert find the latest complete information on supported FCoE configurations?
A. Reference IBM's ServerProven web page
B. IBM System Storage Interoperation Center (SSIC)
C. IBM Flex System product development
D. The FC-BB-5 standards documentation
正解:B
質問 6:
A client wants to see how the 900 GB 10k drives would be used in a RAID 5 set to migrate their 30 TB of storage. Which tool can the technical expert use to show the layout for Flex System V7000 Storage Node?
A. Disk Magic
B. IBM Flex System TCO Analysis
C. Capacity Magic
D. TCOnow! for Disk
正解:C
質問 7:
A government client is migrating to a new network. They want to use as many open standards in their data center as possible. Therefore they want to introduce software-defined networking (SDN). Which communication protocol is supported by the IBM Flex solution that enables SDN?
A. OpenFlow
B. OpenNet
C. OpenStack
D. OpenFlex
正解:A
Osaka -
C4120-784本番の試験は、このIBMの問題集の模擬試験よりはやさしかったようです。
ほぼ、満点に近い点数で合格できました。